Filtered Air Restriction Sensors

To improve the performance of air filtration systems, the NovaSensor FMA Series Filtered Air Restriction (FAR) sensors utilize high-precision NPA silicone piezoresistive technology to accurately measure pressure loss in a variety of air filtration units in a small form factor that is easy to install and maintenance-free.The FAM series features configurable thresholds that allow it to be easily mounted for a wide variety of applications, including commercial and automotive HVAC and industrial air filters, engine air filtration systems, and rooftop units exposed to pressure or vacuum. With waterproof reference ports and sealed connection systems, it can also be used in a variety of harsh environmental conditions.

Characteristic:

  • Operating Temperature Range: -40℃~125℃
  • Expected measuring gas: Clean Dry Air Clean Dry Air
  • Supply Voltage: 5VDC±5
  • Supply current: 5mA Max
  • Voltage Output(V0):0.5 to 4.5V(10%to 90%VDD)
  • Rating: Contact 8kV;Air 15kV
  • Measurable pressure range: 5“/10”/40 ”H20,1/5 PSI
  • Accuracy: ±2.5% FSO
  • Start-up time: 10 ms
  • Response time: <2 ms
  • NPT Female Pressure Mount
  • Integrated AMPSEAL16 (3-way) connector
  • Validated for automotive parts applications

Appliance:

  • Engine Air Filter Monitoring
  • Cabin Pressure
  • Air Conditioning Warm Air Pressure – Tailpipe Pressure
  • Industrial filters

Attached Image:

Ordering Model:


Part Number                                             Standard                                                                                                                                            


FMA 500 T1                  05W:5  in  H20,GV:Vacuum  Gage,GP:Positive  Gage
05W  GV/GP       


 

Similar Posts